J & T Building Management
Evaluation and Repair of Exterior Terra Cotta Facade
Oak Park, Illinois
Structure Evaluation Engineers, Inc.
was retained to perform exterior facade evaluation and repair of the ten-story
historical office building (Medical Art Building) with 100% terra cotta facade in Oak Park. SEE
issued a comprehensive report addressing problems associated with terra cotta
facade and windows,
and presented repair recommendations and cost estimates for the recommended
repair program. After reviewing the investigative report, our client authorized
us to prepare bid documents for the rehabilitation of the terra cotta facade.
SEE
assisted our client in obtaining bids and selecting the contractor.
SEE provided
contract administration and oversaw the rehabilitation work.
Shaker Management Company
Evaluation and Repair of Exterior Terra Cotta Facade
Oak Park, Illinois
Structure Evaluation Engineers, Inc.
was retained to perform exterior facade evaluation and repair of a six-story
office building with 100% terra cotta facade in Oak Park. SEE
issued a comprehensive report addressing problems associated with terra cotta
facade
and presented repair recommendations and cost estimates for the recommended
repair program. After reviewing the investigative report, our client authorized
us to prepare bid documents for the rehabilitation of the terra cotta facade.
SEE
assisted our client in obtaining bids and selecting the contractor.
SEE provided
contract administration and oversaw the rehabilitation work.
Modern Aire Apartments
Evaluation and Repair of Exterior Masonry walls
Oak Lawn, Illinois
Structure Evaluation Engineers, Inc.
was retained to perform exterior facade evaluation of three buildings
at the Modern Aire Apartment complex. The apartment complex included three
buildings with 81 units. SEE
reviewed problems associated with the masonry walls, precast balconies and
walkways. We
issued a comprehensive report addressing problems associated with each building
and presented repair recommendations and cost estimates for the recommended
repair program. After reviewing the investigative report, our client authorized
us to prepare bid documents for the rehabilitation of the exterior masonry and
balcony repair.
SEE
assisted our client in obtaining bids. Due to the high cost of the repair work
our client decided to sale the buildings.
South Commons
High-rise Buildings
Chicago, Illinois
Structure Evaluation Engineers, Inc.
was retained to perform exterior facade evaluation of five high-rise buildings
at the South Commons complex. SEE
issued a comprehensive report addressing problems associated with each building
and presented repair recommendations and cost estimates for the recommended
repair program. After reviewing the investigative report, our client authorized
us to prepare bid documents for the rehabilitation of the high-rise buildings.
SEE
assisted our client in obtaining bids and selecting the contractor.
SEE provided
contract administration and oversaw the rehabilitation work.
West Suburban Hospital
Water Infiltration
Oak Park, Illinois
SEE was
retained to evaluate and repair water infiltration at the professional building.
This office building was built a few years ago and has had water infiltration at
every level. SEE
initially reviewed a limited number of window shop drawings and architectural
drawings to understand the design, installation and anchorage details, and air
and water weep system. Then we briefly reviewed existing condition of the
building and selected a tier that appeared to be the worst to perform a detail
evaluation. SEE
performed water testing from swingstage scaffolding to determine approximate
locations of water infiltration. A masonry contractor removed masonry at these
locations in order to evaluate the hidden condition and detailing.
SEE discovered that
the flashing details were improper. We prepared a new flashing detail with new
flashing material and anchorages. After completion of the repair we performed
water tests to verify watertightness. Based upon successful repair
SEE recommended
allocating funds to repair water infiltration at the remaining areas of the
building.
2020 Lincoln Park West
Condominium Association
Sliding Door Evaluation and Replacement
Chicago, Illinois
Based on the Board’s decision, two sample doors from two different window
manufacturers were installed to evaluate their performance before replacing the
existing balcony sliding glass doors. SEE
was retained to evaluate the performance of the sample doors as well as the
existing sliding doors and make recommendations.
SEE performed a
field evaluation, conducted water testing, reviewed the manufacturer’s
information and discussed the client’s needs. The performance of the doors was
judged based on their maximum structural load capacity, water resistance, air
infiltration, thermal transmittance, and condensation resistance.
SEE issued a
comprehensive report that included findings, comparison, conclusions, and
recommendations with improvements. The Association retained
SEE to oversee the
replacement of the balcony sliding doors.
Wheaton Center
Exterior Facade Rehabilitation
Wheaton, Illinois
SEE provided
specialized structural evaluation of two high-rise buildings with a total of 460
apartment units at Wheaton Center. Our investigative report addressed problems
associated with exterior facades and balconies, provided corrective measures
including concrete repairs, coating and waterproofing, and presented estimated
costs for the recommended repair program. Our client authorized
SEE to prepare bid
documents for Phase I of the construction which included exterior facade
rehabilitation and coating. Due to budgetary constraints, our client decided to
coat the buildings until funds become available to perform the necessary
repairs.
The Habitat Company
High-rise Window Replacement
Chicago, Illinois
The existing aluminum framed windows and sliding glass doors on a residential
high-rise building had reached the end of their useful life.
SEE was retained to
evaluate and prepare detailed specifications for new high performance
architectural rated replacement windows and doors. After evaluating different
manufacturers products, SEE
selected three manufacturers whose products met the requirements of the project.
As part of the bid process, manufacturers were required to install an actual
replacement window and door system on the high-rise. The windows and doors were
then field tested for air and water infiltration (witnessed by
SEE) per the
American Architectural Manufacturers Association Standards. A manufacturer and
contractor were selected and SEE
was retained to review shop drawings, structural design calculations, and
other submittals as well as perform field engineering services during window
replacement.
Blackhawk Stone
Simulated Stone Cornice
Anchorage Design
Wisconsin Electric Power Company
Milwaukee, Wisconsin
Blackhawk Stone was selected by Wisconsin Electric Power Company to provide
intricate cast polymer simulated stone cornice pieces to replace the existing
stone cornice on their historic building in Milwaukee, Wisconsin. Blackhawk
Stone retained SEE
to design an anchorage system to securely suspend the large simulated stone
pieces 80' above the public sidewalk surrounding the building. The anchorage
system had to be easy to install, carry the weight of the pieces and wind loads,
all while allowing each cast polymer piece to freely expand and contract with
temperature changes at a rate 13 times greater than that of limestone.
SEE performed
structural calculations, complete anchorage system design and prepared drawings
for the simulated stone anchorage system.
The Habitat Company
Precast Concrete Balcony
Railing Walls Evaluation
Chicago, Illinois
When a series of high-rise and low-rise buildings were being renovated,
SEE was retained to
evaluate the structural condition of precast concrete balcony railing walls and
their anchorages. The structural integrity of the railing walls was questionable
due to observed corrosion of the anchorages.
SEE performed a field condition survey and
selected representative anchorages for removal and laboratory testing. Based on
the results of the evaluation, SEE
determined a number of repair options including complete replacement and
evaluated initial construction cost and expected life for each repair option.
After reviewing this information, the owner made an informed decision to install
all new architectural aluminum railing systems.
SEE was retained to
design the new railing system and anchorages, and review shop drawings for the
new railings.
Holiday inn
Exterior Masonry Wall Evaluation
Crystal Lake, Illinois
Structure Evaluation Engineers, Inc.
was retained by RFS Hotel Investors to evaluate cracking of this six story
load-bearing masonry structure. After extended monitoring and review of
construction drawings, SEE
determined that daily and seasonal fluctuations in
temperature caused the structure to crack in areas subject to differential
temperature change. SEE
provided an extensive report giving our findings, conclusions and the most
practical methods for limiting further deterioration.
SEE designed
structural restraint systems which accommodate thermal movement for portions of
the building which were structurally compromised.
Cerestar USA, Inc.
Condition Assessment of Refinery Buildings
Hammond, Indiana
SEE
was commissioned to assess the existing condition of four
refinery buildings located within the Cerestar USA facility. The objective of
our assessment survey was to identify visible structural and related
deficiencies and make recommendations on the overall condition of each building.
The buildings were constructed at different times ranging from 1907 to 1962.
Based on the operational requirements and the extent of deterioration in each
building, SEE
concluded that only one building could be repaired cost
effectively and it would be most cost effective to demolish and re-construct the
other three buildings. Due to the severe deterioration observed,
SEE made
emergency recommendations that included immediate shoring and implementation of
a monitoring program until repairs are made or the buildings are demolished. Our
client hired SEE
to oversee the installation of the emergency shoring and monitor the buildings
until funds become available.
W.M. Construction, LP
Masonry Wall Collapse Evaluation
St. Charles, Illinois
During a severe storm, a masonry wall of a four unit townhouse under
construction collapsed. The collapse severely damaged a substantial
portion of the structural framing for three stories including roof
framing as well as an interior concrete foundation wall.
SEE
performed a field evaluation to assess the extent of the damaged
areas. All structural framing for two units was removed.
SEE
determined that the remaining framing was undamaged and had remained
vertically plumb. SEE
also reviewed the foundations in the
affected area and determined that no significant structural movement
or damage was sustained. SEE
designed a reinforced masonry wall to replace the collapsed interior
concrete wall. SEE’s
rapid evaluation and replacement wall design allowed the
construction to continue with minimal delays.
Marcal Paper Mills, Inc.
Exterior Masonry Wall Evaluation
Chicago, Illinois
Upon receiving a citation from the
building department, Marcal Paper Mills contacted
SEE to
perform an evaluation of the condition of an exterior masonry wall adjacent to a
public sidewalk. SEE
performed a field evaluation which consisted of accurately documenting vertical
profiles of the wall at regularly spaced intervals as well as performing
selective observation openings in the wall to observe mortar condition, wall
thickness, and condition of steel lintels. Our findings indicated that the wall
was severely deteriorated and had leaned and bowed up to 4" in various areas due
to significant amounts of water entering the wall and deteriorating the mortar
in the past. SEE
recommended complete replacement of the wall as the most cost-effective repair
solution.
American Maize-Products Company
Feasibility and Cost Analysis
for Corn Silos
Hammond, Indiana
Structure Evaluation Engineers, Inc.
was retained to perform feasibility and cost analysis for 14 concrete corn
silos. Our client wanted to maintain these silos for a period of five years.
SEE developed
a comprehensive list of necessary structural repair items for each silo that
will allow operation for five years. Also,
SEE prepared a detailed cost analysis for various
alternates that helped our client to plan and budget for future expansion and
modification.
L.J. Sheridan Company
Luxury Apartment Complex
Chicago, Illinois
Structure Evaluation Engineers, Inc.
was retained by L.J. Sheridan Company to evaluate a floor settlement problem
inside a new luxury apartment complex in Chicago, Illinois. Through field
investigation and soil sampling, we determined that 4 feet of sand fill had been
placed on the site and was not properly compacted. As the sand consolidated
under its own weight as well as the applied loads, settlement occurred.
SEE provided a
written report giving our findings, conclusions, and the most practical method
of preventing further settlement. Following the successful implementation of our
recommendations. SEE
were further retained to evaluate floor settlement in an apartment on the
opposite end of the complex. Field investigation and soil sampling indicated
that loose rubble fill had been placed beneath the slab on grade in this area.
Consolidation of this fill, coupled with cracked drainage pipes and migration of
fine soil particles within the soil was determined to be the cause of the
settlement. SEE
prepared a written report that included our findings and conclusions and
produced detailed repair documents for soil treatment and replacement of the
slab on grade in the affected unit.
Q & W Management
Capital Reserve Study
Tinley Park, Illinois
SEE was
retained to perform a capital reserve study for two buildings with 24 units
located in Tinley Park, Illinois. The study was initiated as a result of
converting the units to condominiums. SEE
performed a field condition survey of common structural, mechanical, electrical,
plumbing, and fire protection items as well as individual unit mechanical,
electrical, and general maintenance items. A comprehensive report was issued
that included a summary of each element and schedules for common and general
maintenance elements. The schedules included description, approximate age,
condition of the item at the time of review, average useful life, approximate
number of years until repair or replacement, and estimated repair or replacement
cost for a twenty year period. The report also included a 1 to 10 year fund
allocation schedule for the common structural, mechanical, electrical, plumbing,
and fire protection elements.
Northwestern University Chicago Campus
Flag Pole Evaluation
Chicago, Illinois
SEE performed
a structural evaluation of the flag pole that was mounted on the roof of a 16
story building. The flag pole consisted of nine telescoping steel tube sections
with a total height of 160 feet. Ultrasonic thickness testing was performed to
determine pole wall thickness and to identify hidden corrosion of the pole.
SEE
recommended strengthening the pole at several locations due to corrosion. The
investigative report included findings, recommendations, cost estimates and cost
for removing the flag pole completely. Our client decided to repair the flag
pole. SEE
prepared repair documents and oversaw construction work.
2020 Lincoln Park West
Condominium Association
Pool Gutter Renovation and Lining
Chicago, Illinois
The existing steel pool gutter which incorporated an integral deck drain was
severely deteriorated. In particular, the separation plate between the two
gutter systems was extensively corroded. Hence, gallons of treated pool water
was lost every day. Additionally, runoff water entering the deck drain was
infiltrating and contaminating the pool water. No construction information was
available on this unique 25 year old steel wall and concrete base pool.
SEE developed an
evaluation program to investigate and rehabilitate the pool. Our solution
replaced the old steel gutter with an efficient self skimming stainless steel
gutter and included installation of a 60-mil thick reinforced PVC pool liner.
Village Shopping Center
Evaluation and Study of Walkways
Chicago, Illinois
Exterior reinforced concrete walkways provided access to the second floor
stores. The walkways were cantilevered from the building and exhibited concrete
deterioration. Our client wanted to know if the walkways and stairs could be
repaired or need to be replaced. They also wanted to know if the construction
work could be performed without closing access to the second floor especially to
the restaurants which are open for breakfast, lunch and dinner. After reviewing
field conditions and considering ADA requirements,
SEE concluded that
it was most cost effective to replace the walkways and stairs. Several different
options were studied and it was determined that precast concrete walkways serve
our client’s needs best and access to the second floor will be maintained at all
times during construction.
Royal Glen Condominium Association
Swimming Pool Rehabilitation
Glen Ellyn, Illinois
When the existing pool supply piping was no longer functioning properly, our
client retained the services of SEE
to design a rehabilitation program to allow use of the pool. The pool supply
piping buried under the concrete pool was severely corroded and had to be
replaced. To access the deteriorated piping, a trench was cut through the
concrete down the center of the entire pool.
SEE designed a new PVC buried piping system as
well as the necessary reinforcing to structurally tie the pool back together.
Other concrete repairs and sealant replacement was specified. The pool was back
in operation and functioning properly after rehabilitation.
350 W. Hubbard Building
Structural Slab Conduit Trench Evaluation
Chicago, Illinois
Structure Evaluation Engineers, Inc.
was retained to evaluate the structural integrity of a supported slab in which
conduit trenches were chipped into the concrete to allow new conduit placement.
SEE performed
a field investigation and reviewed structural drawings. Our evaluation
determined that the slab was a composite steel and concrete system.
SEE issued a report
detailing repair procedures and materials which addressed the size and location
of new conduit to be placed in the trenches, the treatment of exposed shear
studs, the preparation of trench surfaces for repairs, and proper repair
materials.
1630 Sheridan Corporation
Cantilevered Entrance Canopy
Evaluation and Repair Design
Wilmette, Illinois
When corrosion had taken its toll on portions of two 10' x 15' steel
framed cantilevered entrance canopies, the 1630 Sheridan Corporation
contacted SEE
to evaluate the condition of the canopy.
SEE
visited the site and performed a field condition survey of the
canopy main framing members. The open top steel gutter system around
the canopy skylights and the main structural frame anchorage bolts
were severely deteriorated. Upon completion of the field condition
survey, SEE
designed repairs to the corroded gutter system and supplemental
anchorages to properly transfer the cantilevered canopy loads to the
supports. SEE
issued a report which contained our field observations, conclusions,
and detailed repair recommendations for the two canopies.
Investors Home Reality
Evaluation and Repair
Design for Exterior Balconies
Elgin, Illinois
Investors Home Reality retained SEE
to evaluate the cantilever exterior timber balconies
on three separate buildings. The cantilever timber balcony joists were the
continuation of non-pressure treated floor joists within the building.
SEE performed a
field condition survey to document the extent of deterioration on the
cantilevered joists. SEE
designed an innovative repair detail for the joists that did not have
deterioration beyond the mid point, be repaired from the exterior thereby
resulting in a substantial savings to our client. For the joists with
deterioration over the full cantilever length,
SEE designed a repair that minimized the work
within the buildings.
Henry Martinez
Commercial Property
Joliet, Illinois
SEE was
retained to evaluate termite damage to the first floor level timber framing of
this property. After evaluating the existing condition of the beams and columns,
SEE concluded
that the extent of termite damage was wide-spread and structural members had
suffered significant damage. It was determined from our evaluation that the
floor boards could remain, but the floor joists needed replacement.
SEE recommended
repair options that allowed continued use of the retail unit above during the
repair process, minimized disruption of utilities routed beneath the floor, and
did not restrict headroom in the basement below.
Woodridge Village Hall
Prepurchase Assessment
Woodridge, Illinois
When a mortgage company was considering purchasing the existing Village Hall
Building in Woodridge, SEE
was retained to do a prepurchase assessment of the roofing, masonry facade and
roof structural framing. SEE
performed field observations to identify and document areas with visible
deficiencies. Following documentation, SEE
prepared a detailed report which described the general condition of the elements
observed and listed all observed deficiencies. Our report also included a
comprehensive repair cost estimate to help our Client in negotiating the final
purchase price.
Madison Warehouse Corp.
Existing Condition Assessment
Joliet, Illinois
SEE
was retained to assess existing conditions of
the floor and precast wall panels at this 480,000 square feet warehouse
building. The new warehouse building showed wall panels movement and floor
settlement that hindered the forklift traffic. Hence a grouting contractor was
retained to mud jack the floor slab. After mud jacking the floor slab exhibited
cracking and precast wall panels showed movement.
SEE was
asked to review existing conditions and make corrective recommendations. After
assessing the existing condition and reviewing the designed documents
SEE
determined that the precast wall panels were not anchored to the foundation
properly and mud jacking made the conditions much worst. Many of the precast
wall panels were moved out at the bottom by more two inches. We recommended a
comprehensive repair program along with cost estimate.
Mason Corporation
Evaluation and design of exterior walls
West
Chicago, Illinois
S
EE
was retained to evaluate and design structural modifications to the exterior
wall of an industrial building being converted to office space. The evaluation
and design included the removal of existing structural framing members in the
wall to allow for installation of eight new windows up to 17' long and 4' tall.
SEE
analyzed the existing framing and designed new framing to efficiently transfer
the loads from the removed existing framing and new window systems.
Additionally, SEE
designed a strengthening system to support deficient original roof framing near
the new window openings.
Madison Warehouse Corp.
Prepurchase Assessment
Joliet, Illinois
SEE
was retained to do a prepurchase assessment of the floor slab, precast wall
panels and
roof framing of this new warehouse building in Joliet. The warehouse building
was approximately 280,000 square feet. SEE
performed field observations to identify and document areas with visible
deficiencies. Following documentation, SEE
prepared a detailed report which described the general condition of the elements
observed and listed all observed deficiencies. Our report also included a
comprehensive repair cost estimate to help our Client in negotiating the final
purchase price.
© Copyright,
1994-2012, Structure Evaluation Engineers, Inc.