Fireman’s Fund Insurance Co.
Wespark Townhomes
Romeoville, Illinois
After a natural gas explosion that damaged approximately 100 townhomes
SEE was retained to
assess blast related damage to structural components, determine the extent of
the damage, and provide litigation support. We immediately recommended emergency
shoring during our initial walk-thru in order to provide safe access for our
close-up observations. We reviewed original construction drawings, shop
drawings, product data and material information, code and regulatory
requirements, and reports prepared by other engineering firms.
SEE prepared a
report for blast related damages and repair recommendations for each townhome
and a separate report for code non-compliance items. We worked very closely with
the lead counsel and regional general adjuster to identify and analyze claim
issues and construction defects.
Confidential Client
Litigation and Expert Witness
Chicago, Illinois
Structure Evaluation Engineers, Inc.
was retained to provide forensic engineering services to evaluate
and review a multi-million dollar construction law suit. The scope of work
includes review of original documents, construction documents, construction
techniques, material evaluation, manufacturer’s literature, etc.
SEE worked closely
with the attorneys of the Architect and provided objective expert witness
services that resulted in a settlement in favor of our client.
Walter Murphy Residence
Litigation and Expert Witness
Orland Park, Illinois
SEE was
retained to provide an independent opinion on the basement slab cracking, and
general comments on the potential slab and foundation wall settlement. Our
client wanted to make sure that the newly built, half million dollar house was
structurally adequate and sound. After performing field condition survey and
reviewing design documents, SEE
concluded that the floor cracking was due to drying shrinkage and slab curling.
Additionally, the basement floor slab was not built per design drawings.
SEE recommended
replacing the floor slab. The soil borings indicated an unstable soil layer
below the foundation. SEE
recommended that the developer open observation pits along foundation walls to
document the as-built foundation footings and retain services of geotechnical
engineering firm to perform calculations either to show that the expected
long-term settlement is within allowable limits or to design required
underpinning details.
Confidential Client
Litigation and Expert Witness
Braidwood, Illinois
Structure Evaluation Engineers, Inc.
was retained to provide forensic engineering services to evaluate and review an
underground construction law suit. The scope of services included review of
original documents, construction techniques, material evaluation, field
measurements, code review and code compliance.
SEE worked closely with the attorneys of the
contractor and provided objective litigation services as the law suit
progressed.
Blast Deflectors, Inc.
Chicago Ground Run-up Enclosure
Watsonville, California
Structure Evaluation Engineers, Inc.
was retained to peer review the design drawings and
structural calculations for the O’Hare Ground Run-up Enclosure. The enclosure
walls were 40-foot high A-frame trusses that enclosed an area of 280 feet by 262
feet on three sides. The subject structure will be used to test aircraft and
reduce noise levels. After reviewing the documents and calculations,
SEE issued a report
that included our conclusions and recommended revisions. Recommendations
included ice loading calculations, connection modifications and revised
foundation attachment details. At the request of the manufacturer,
SEE modified the
drawings and reissued new drawings for construction.
Aurora Housing Authority
Condition Survey of Structural Modifications
Aurora, Illinois
SEE was
retained to perform a condition survey of structural modifications at
approximately 20 units of various apartment buildings. Our task was to determine
exactly what structural modifications had been performed at each location. We
documented the structural modifications with video tape as well as drawings.
SEE then
prepared a detailed condition survey report which compared the actual
strengthening performed with the work that was specified to be performed at each
unit.
Timothy J. McCann Attorney at Law
Grosskopf Residence
Oswego, Illinois
SEE was
retained to perform structural evaluation of the foundation wall that was
cracked and bowed a year after construction.
SEE took concrete core samples and reviewed
cracking patterns. SEE
determined that the foundation wall was poured during cold weather and was not
protected. The petrographic results indicated the concrete was frozen. Also,
core samples revealed that the epoxy injection of the cracks was not performed
properly and there was no epoxy material at several locations.
SEE concluded that
the contractor backfilled before the concrete had reached adequate strength. The
investigative report addressed the problems and recommended corrective measures
and included a cost estimate.
The Ritter Group
Fire Damage Evaluation
St. Charles, Illinois
Our client contacted
SEE
to perform an evaluation of damage resulting from a fire at his home. Based on
our initial visit, SEE
prepared a report highlighting worst damaged areas and made recommendations
regarding further exploration to determine the full extent of damage. After
review of the report, our client retained
SEE to make engineering representations on his
behalf during the insurance claim process.